1
HiPath - 3000 / 5000 / Re: Hipath 3008 - ISDN NETMOD Config
« on: July 23, 2013, 11:38:51 pm »
hello
Alessandro it is right, let me explain:
I have an Siemens Optipoint 500 Advance for Reception and phone extension does not work. In Hipath Manager I can program numbers. It is connected to 500 Advanced via cable on the correct port. I need to make something special for extension to function?
Alessandro it is right, let me explain:
- ISDN backpack connector 8 with RJ45 was not connected in the right Hipath Expansion Box Slot, it should be conected in 4 but it was conected in 5.
- Backpack conector was the version for Internal digital telephones. For ISDN need to be crossed
- ISDN line must be defined as S0 Euro CO PMP. See attach where you find this option
- I had also ISDN 2 GSM Device by Topex. (ISDN Bri Gateway). On this device the PORT TE must be conected with STMD3 via crossover ISDN cable, and SYNC PORT (clock signal synchronization port) must be conected in ISDN device. Manual it is here: http://www.topex.ro/en/get_file?idFile=3112
I have an Siemens Optipoint 500 Advance for Reception and phone extension does not work. In Hipath Manager I can program numbers. It is connected to 500 Advanced via cable on the correct port. I need to make something special for extension to function?